Fault Name |
Possible Reason |
Exclusions |
|
Intermediate Wire drawing machine can’t work |
The power switch is off No reset when machine stop for wire break and length break Emergency button is on Inverter fault |
Turn on power switch just reset Turn off the emergency button 4.1 According to parameter on the inverter screen and manual of the inverter, solve it. Turn off the power switch, restart after 30s |
|
Wire break frequently |
Wrong dies arrangement Too high speed Bad raw material Metamorphic lubrication Burrs on the bobbin Pay-off is not smooth Too high pay-ff speed Sticky wire on capstan |
Arrange die according to machine slip ratio. Slowdown Change raw material Change lubrication Use ethanol and sand paper to clean the bobbin Adjust the position of pay-off stand Enlarge inlet diameter or slowdown Clean capstan by alcohol |
|
Wire break at certain position |
Wrong slip ratio Wrong die size The dies and guide wheel are not in the same line |
Arrange die according to machine slip ratio Repair or change die change the position of dies |
|
Re-tension not rising |
The meter reset button is not pressed after changing discs |
Restart after pressing the meter reset button |
|
Traversing not good |
1. The width of the traversing is not adjusted properly 2. Traversing motor failure 3. The limit switch is in poor contact 4. Traversing speed |
1. Adjust the traversing width 2. Check the traversing motor and its circuit 3. Replace the limit switch 4. Adjust the traversing speed according to the drawn wire diameter and speed |
The above are some Common Faults and Elimination of Intermediate Wire Drawing Machine shared by Brainpower with you.
If you have better ideas, you can contact:sunman@brwiremachine.com